QA-OMNİ
- Input:1 Digital and 1 analogue at the same time
- Voltage: 0…10 V, Programmable, input impedance 100 kohm, resolution 1 mv.
- Current: Up To 20 ma, programmable, input impedence 20 ohm, max resolution 2 μa;
- Temperature: rtd pt100, pt500, pt1000, ni100. 2, 3 or 4 wire measurement, automatic detection of cable interruption, 400 or 4000 ohm. tc type j, k, r, s, t, b, e, n; automatic detection of tc interruption, from -10 mv to +70 mv.
- Potentiometer: From 1000 ohm to 10 kohm.
- Frequency: from 0.001 hz to 9.99 khz, mechanical contact, npn 2 and 3 wires, pnp 3 wires with 24 vdc power supply, namur, photoelectric, hall sensor, variable reluctance, pulses 24 v, ttl.
- Output: 1 Analogue, 1 Digital, 1 Rs485 at the same time
- Current: 0…20 Ma, Programmable, Maximum load resistance 600 Ohm.
- Voltage: 0…10 V, Programmable, Minimum load resistance 2 Kohm.
- Contact Alarm: Spdt 5a 230 vac relay, configurable using the facıle qa-omnı software.
- Rs485 Modbus: Rs485 serial bus connection on the bottom of module by adapter (optional) or on terminals. Front dip-switch for manual setting of address and baudrate.
ERCAN TEKNIK COOLING TECHNOLOGIES INCORPORATION ERCAN TEKNIK COOLING TECHNOLOGIES INCORPORATION ERCAN TEKNIK COOLING TECHNOLOGIES INCORPORATION
YOU MAY CALL US or
INTERESTED IN?
- Description
- User's Manual
Description
Universal signal converter, usb configurable, dın rail mounting, 4-way galvanic isolation, universal power supply ac/dc, programmable alarm contact, rs485 modbus. Data logging function which saves data to a usb pen drive. they are downloaded in a format which can be imported into excel (built-in rtc real time clock). Simultaneous analogue and digital input. measures current, voltage, frequency, potentıometer, temperature (rtd and tc).
Click For Manual
QA-OMNİ
- Input:1 Digital and 1 analogue at the same time
- Voltage: 0…10 V, Programmable, input impedance 100 kohm, resolution 1 mv.
- Current: Up To 20 ma, programmable, input impedence 20 ohm, max resolution 2 μa;
- Temperature: rtd pt100, pt500, pt1000, ni100. 2, 3 or 4 wire measurement, automatic detection of cable interruption, 400 or 4000 ohm. tc type j, k, r, s, t, b, e, n; automatic detection of tc interruption, from -10 mv to +70 mv.
- Potentiometer: From 1000 ohm to 10 kohm.
- Frequency: from 0.001 hz to 9.99 khz, mechanical contact, npn 2 and 3 wires, pnp 3 wires with 24 vdc power supply, namur, photoelectric, hall sensor, variable reluctance, pulses 24 v, ttl.
- Output: 1 Analogue, 1 Digital, 1 Rs485 at the same time
- Current: 0…20 Ma, Programmable, Maximum load resistance 600 Ohm.
- Voltage: 0…10 V, Programmable, Minimum load resistance 2 Kohm.
- Contact Alarm: Spdt 5a 230 vac relay, configurable using the facıle qa-omnı software.
- Rs485 Modbus: Rs485 serial bus connection on the bottom of module by adapter (optional) or on terminals. Front dip-switch for manual setting of address and baudrate.
- Description
- User's Manual
Description
Universal signal converter, usb configurable, dın rail mounting, 4-way galvanic isolation, universal power supply ac/dc, programmable alarm contact, rs485 modbus. Data logging function which saves data to a usb pen drive. they are downloaded in a format which can be imported into excel (built-in rtc real time clock). Simultaneous analogue and digital input. measures current, voltage, frequency, potentıometer, temperature (rtd and tc).
Click For Manual