QE POWER-M

  • Power Supply: 10…40 V DC or 19…28 V AC – 50/60 Hz
  • Voltage Input: Direct connection up to 500 V RMS max (40…70 Hz)
  • Configurable transformation ratio for CT and VT
  • OUTPUTS: RS485 Modbus RTU and SPST digital contact (< 40 V, <100mA)
  • Avaılable Measurements (STD and PLUS): Irms, Vrms, Ipk, Vpk
  • Active power (W)
  • Reactive power (VAR)
  • Apparent power (VA)
  • Frequency
  • Power factor (inductive/capacitive)
  • Energy (kWh)
  • Bidirectional energy (kWh), positive and negative
  • Active and reactive energy (kVARh), inductive/capacitive
  • Crest factor
  • Tanφ per phase and average (inductive/capacitive)
  • Power factor average
  • Power factor distortion (inductive/capacitive) and average
  • THD (V, I )
  • Min, average and max power measurements
  • Max demand over 15 minutes
  • Time of max demand (monthly) (month, day, hour, minutes)
  • Time above a threshold.
ERCAN TEKNIK COOLING TECHNOLOGIES INCORPORATION ERCAN TEKNIK COOLING TECHNOLOGIES INCORPORATION ERCAN TEKNIK COOLING TECHNOLOGIES INCORPORATION
YOU MAY CALL US or

INTERESTED IN?

Description

The QE-POWER-M is the single-phase version of the QE-POWER-T, the smallest single-phase power meter which is able to manage any current sensor (1 / 5 A, 333mV, Rogowski probes).

It is ready to be integreated into monitoring and data logging systems.

RS485 Modbus RTU output and configurable digital contact available (window alarm threshold). The product has two versions (STD and PLUS) that can meet all measurement needs. And it provides a universal input for current transformers.

qe-power-m
qe-power-m-2
qe-power-m-3

QE POWER-M

  • Power Supply: 10…40 V DC or 19…28 V AC – 50/60 Hz
  • Voltage Input: Direct connection up to 500 V RMS max (40…70 Hz)
  • Configurable transformation ratio for CT and VT
  • OUTPUTS: RS485 Modbus RTU and SPST digital contact (< 40 V, <100mA)
  • Avaılable Measurements (STD and PLUS): Irms, Vrms, Ipk, Vpk
  • Active power (W)
  • Reactive power (VAR)
  • Apparent power (VA)
  • Frequency
  • Power factor (inductive/capacitive)
  • Energy (kWh)
  • Bidirectional energy (kWh), positive and negative
  • Active and reactive energy (kVARh), inductive/capacitive
  • Crest factor
  • Tanφ per phase and average (inductive/capacitive)
  • Power factor average
  • Power factor distortion (inductive/capacitive) and average
  • THD (V, I )
  • Min, average and max power measurements
  • Max demand over 15 minutes
  • Time of max demand (monthly) (month, day, hour, minutes)
  • Time above a threshold.

Description

The QE-POWER-M is the single-phase version of the QE-POWER-T, the smallest single-phase power meter which is able to manage any current sensor (1 / 5 A, 333mV, Rogowski probes).

It is ready to be integreated into monitoring and data logging systems.

RS485 Modbus RTU output and configurable digital contact available (window alarm threshold). The product has two versions (STD and PLUS) that can meet all measurement needs. And it provides a universal input for current transformers.